Determining Caster Value

AR40.20-P-0322-03EW Check caster and assign to tabular value

Modification Note

Tolerance for caster ±30'
The level values are displayed by the electronic inclinometer in decimal degrees [°].

1

Obtain the caster value from the table taking into account the front axle (FA) level values and rear axle (RA) level values measured previously.

Example, see Table: 

Front axle level value (FA): +1.6° 
Rear axle level value (RA): +0.6°
= Caster value 6° 54' ( ±30')