mercedesbenz Workshop Repair Guides

Mercedes Benz E 350 Coupe V6-35L Workshop Service and Repair Manuals

Determining Caster Value|Page 145 > < Electrical - Electrostatic Discharge Damage Prevention
Page 1
background image

Alignment: Specifications
Determining Caster Value

AR40.20-P-0322-03EC Check caster and assign to tabular value

Check and adjustment values for caster

Tolerance for caster ±30'

The level values are displayed by the electronic inclinometer in decimal degrees [°].

1

Obtain the caster value from the table taking into account the front axle (FA) level values and rear axle (RA) level values measured previously.

Example, see Table: 

Front axle level value (FA): +4.1 degrees 
Rear axle level value (RA): +0.4 degrees 
= Caster value 10 degrees 44' ( ±30')

Determining Caster Value|Page 145 > < Electrical - Electrostatic Discharge Damage Prevention