30. Route red/black line (rt/sw) from Bowden cable (24) of foot operated parking brake along the vehicle wiring harness to the front SAM control unit

with fuse and relay module.

31. Fasten red/black line (rt/sw) using cable ties (28) to vehicle wiring harness.

32. Remove pink connector (5C) from front SAM control unit with fuse and relay module (N10/1).
33. Install plug contact (12) of red/black line (rt/sw) into slot "11" (arrow H) of pink connector (5C).
34. Connect pink connector (5C) to front SAM control unit with fuse and relay module (N10/1).
35. Install 7.5 amp fuse into slot 36 on front SAM control unit with fuse and relay module (N10/1).

AN54.30-P-0001-03EW Retrofit Night View Assist control unit

AN54.30-P-0001-03EW Retrofit Night View Assist Control Unit

1. Connect black 6-pin connector (1) of wiring harness for power supply (5) to Night View Assist control unit (N101).
2. Connect violet 2-pin connector (2) of wiring harness for power supply (5) to Night View Assist control unit (N101).
3. Connect silver 10-pin connector (3) of low voltage differential signal (LVDS) line (4) to Night View Assist control unit (N101).

The silver 10-pin connector (3) of the LVDS line (4), which is located in the vicinity of the white length reference marking (arrow), is to be used.