E 350 Sedan (212.056) V6-3.5L (272.980) (2010)
The fuse carrier (19) is no longer required.
5
Disconnect orange connector C11 (arrow A) on front SAM control unit with fuse and relay module (N10/1) and install supply line tie-out (18)
with pin "SLK 2.8X0,8" in chamber 6 (arrow B) on orange connector C11.
6
Place illuminated door sill molding control unit (1) in front passenger footwell.
7
Connect black 33-pin coupling (8) from wiring harness for supply (3) with illuminated door sill molding control unit (1).
8
Connect white 6-pin coupling (10b) of wiring harness for supply (3) with white 6-pin plug (10a) of wiring harness for illuminated door sill
molding (2).
9
Connect ground (16) of wiring harness for supply (3) to the ground point of right footwell (W15/1).
A maximum of 5 connectors may be connected to a ground point. In the event of over-assignment another ground point should be selected.