mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF83.40-P-3000FLA Component Description For Automatic Air Conditioning Control and Operating Unit|Page 8188 > < GF83.40-P-3000FLA Component Description For Automatic Air Conditioning Control and Operating Unit|Page 8186
Page 4
background image

Direct line

The following sensors are read in via a direct line:

-

Interior temperature sensor (B10/4)

-

Evaporator temperature sensor (B10/6)

-

Left side air vent air outlet temperature sensor (B10/31)

-

Right side air vent air outlet temperature sensor (B10/32)

-

Left front footwell vent air outlet temperature sensor (B10/35)

-

Right front footwell vent air outlet temperature sensor (B10/36)

-

Sun sensor (B32/3)

-

Interior temperature sensor with integrated fan (N70/3b1) (without code (414) Power glass tilting/sliding roof)

Climate control LIN

The following sensor is read in via climate control LIN:

-

Vehicle interior humidity/temperature sensor (B82) (model 212.2 as of 1.12.2009 and model 212.0 as of YoM 09/2 as of 1.12.2009)

Interior CAN

The following signals are read in over the interior CAN:

-

Provided by instrument cluster (A1):
-

Vehicle speed

-

Provided by radio with auto pilot system (A2/56) (with code (511) Audio 50 APS with DVD changer) or by COMAND controller unit (A40/3)
(with code (512) COMAND APS with DVD changer or with code (527) COMAND APS with single DVD drive (with navigation)):
-

Status of voice control system (VCS)

-

Provided by front SAM control unit with fuse and relay module (N10/1):
-

Coolant temperature sensor (B11/4)

-

Refrigerant pressure sensor (B12)

-

Outside temperature sensor (B14)

-

Engine speed

-

Provided by the overhead control panel control unit (N70):
-

Interior temperature sensor with integrated fan (N70b1) (with code (414) Electric glass tilting/sliding roof)

-

Provided by electronic ignition lock control unit:
-

Status of circuit 15

Evaluation of input factors

The input factors that have been read in are evaluated by the integrated microprocessor and the affected components are then actuated.

Actuation of components

Components are actuated via the following lines:

^

Direct line

^

Climate control LIN

^

Interior CAN

Direct line

The following component is actuated via a direct line:

-

Blower regulator (A32n1)

Climate control LIN

The following components are actuated via climate control LIN:

-

Fresh air/recirculated air flap actuator motor (M2/5)

-

Left blend air flap actuator motor (M2/6)

-

Right blend air flap actuator motor (M2/7)

-

Defroster flap actuator motor (M2/16)

-

Air distribution flap actuator motor (M16/22)

-

PTC heater booster (R22/3) (with engine 271.8, 642.8 or 651.9)

Interior CAN

The following components are actuated with the interior CAN:

-

From the rear SAM control unit with fuse and relay module:

GF83.40-P-3000FLA Component Description For Automatic Air Conditioning Control and Operating Unit|Page 8188 > < GF83.40-P-3000FLA Component Description For Automatic Air Conditioning Control and Operating Unit|Page 8186