Page 14
background image

Check Values For Propeller Shaft Inclination Angle

Memory Screen

The display indicates that the meter is ready to measure angle 5. This angle is no longer measured.

1

Press the MEMORY button once.

The main menu is displayed.

2

Press the MEMORY button again.

The memory displays the measured angle (a, b, d) and the resulting articulation angle 1 (c) and articulation angle 2 (e).

3

Record inclination angle 1 (c) e.g. +0.26 degrees and inclination angle 2 (e) e.g. +0.58 degrees on the data sheet.

4

Press the STEP button.

Memory screen