mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF68.50-P-0004-01FL Roller Sun Blind, Location of Components|Page 11660 > < GF68.50-P-0004-01FL Roller Sun Blind, Location of Components|Page 11658
Page 2
background image

Normalization is actuated each time blockage is detected outside the normalization procedure.
If position marker values are not plausible (e.g. startup of new rear SAM control unit or new control unit software), normalization is also actuated. In this
case it is necessary to actuate both mechanical stops.

This is accomplished as follows:

-

The position marker is set to zero for both stops.

-

The first stop is actuated the next time the function is actuated.

-

The position marker of the other stop is set to zero after the end of the actuation.

-

The second stop is actuated the next time the function is actuated. Now the normalization procedure is terminated.

Function sequence for manual actuation of normalization

When the rear window roller sun blind button is actuated until the end of the actuation, manual normalization is actuated.
This actuates the rear window roller sun blind motor and switches off by the blockage detection. The next time the function is actuated, an automatic
normalization procedure is started.

Function sequence for time control

The rear window roller sun blind motor is actuated for t = 0 to 20 s by the rear SAM control unit regardless of the running direction of the roller sun
blind.
At an on-board electrical system voltage of U < 10.5 V the actuation is increased by t = 2 s to ensure that it moves to the end position even under
unfavorable conditions (low temperatures, sluggishness).
After expiration of this time the request is automatically terminated.

If the rear window roller sun blind button is actuated continuously for t > 30 s, this is recognized as "sticking". An error is stored in the rear SAM control
unit and the signal is no longer relayed to the interior CAN.

Function sequence for temperature protection

Each request from the rear window roller sun blind motor is stored in the rear SAM control unit. If more than one request is present within a specified
time, they are listed and compared with the threshold value stored in the rear SAM control unit. If the threshold value is exceeded, the rear SAM control
unit switches off the rear window roller sun blind motor to prevent overheating.
A new request from the rear window roller sun blind motor is only possible after a cooling time stored in the rear SAM control unit.

Function sequence for emergency operation

If the value from the location counter is implausible, the rear window roller sun blind motor changes to emergency operation When changing to
emergency operation, both position markers are set to zero so that a normalization can be started the next time possible.

Function sequence: error storage

If a defect is detected, the hardware outputs on the rear SAM control unit are deactivated until the next change c. 15R ON/OFF takes place.

To simplify troubleshooting in the event of implausible behavior of the roller sun blind, the following function statuses are edited for output via diagnosis
or parameter acquisition.

Function sequence for fault storage comprises the following subfunctions:

^

Function sequence for current fault

^

Function sequence for last fault

^

Function sequence for last stopping reason

^

Function sequence for last actuation duration

^

Function sequence for maximum actuation duration

^

Function sequence for maximum power

^

Function sequence for motion counter

Function sequence for current fault

The status of the function requirements is stored with each request. If not actuated, it is easy to determine which condition was not fulfilled when the last
button was pressed. This allows a current problem to be solved.

Function sequence for last fault

The status of the requirements is stored permanently if the system is not actuated after a request due to non-fulfillment of function requirements.
This allows determination of the cause of a one-time malfunction. This value is overwritten only by a new combination of unfulfilled requirements.
Status of c. 15 is not considered, because it is generally an incorrect operation which should not overwrite actual errors.

GF68.50-P-0004-01FL Roller Sun Blind, Location of Components|Page 11660 > < GF68.50-P-0004-01FL Roller Sun Blind, Location of Components|Page 11658