Auxiliary Water Pump: Description and Operation
Coolant Circulation Pump

The coolant circulation pump serves for maintaining a uniform flow of heating water through the heater core even at low engine speeds and in the
residual engine heat utilization mode.

Function in heating mode 
The quantity of coolant pumped to the heater core with the engine running depends on the coolant pump. The coolant circulation pump ensures that the
water flows through the heater core uniformly without bubbles even at low speeds.
The coolant circulation pump is controlled by the push-button control module.

Function with residual engine heat utilization 
The coolant circulation pump pumps the heated coolant to the heater core when the engine is standing still. When the REST button is pressed the
temperature is controlled by the push-button control module (in the same manner as when the ignition is ON). 
The push-button control module switches the electric motor for the coolant circulation pump which drives the impeller via a magnetic clutch.