mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Oil Level Warning Indicator > < Loud Rattling Noise During Cold Start
Page 1
background image

Oil Filter Housing: Service and Repair

Removal/Installation:

NOTE:  Each step applies to both, models 124 and 210, unless stated otherwise in the specific step.

-

Disconnect ground cable at battery, connect.

-

Model 124: remove intake air hose on right (17).

-

Model 210: remove air cleaner housing.

-

Unscrew bolt (1) of oil filter cap. 

Tighten to: 20 Nm.

-

Remove oil filter cap (3) together with bolt (1), so that engine oil in oil filter (6) flows off into sump.

-

Replace seal (4).

-

Disconnect electric wiring at generator.

-

Model 124: unplug plug connection of oil pressure sensor (135).

-

Model 124: unbolt oil pressure sensor (B5) with connection cable (15).

Tighten to: 25 Nm.

-

Model 124: replace seals (14) according to condition.

-

If air-oil cooling fitted: unbolt oil pipes (7) and (8) of air-oil cooler at oil filter (5).

Tighten to: 7 Nm.

-

Replace seals (9).

-

Unbolt oil filter housing (5) at crankcase.

Installation Note:  Install bolt (10) with bracket (2) for generator wiring harness.

-

Remove oil filter housing (5) downward.

-

Clean sealing surfaces.

-

Replace gasket (5a).

-

Install in reverse sequence, observing tightening specifications and the installation note.

-

Check, adjust engine oil level to correct level.

-

Run engine and check for leaks.

Oil Level Warning Indicator > < Loud Rattling Noise During Cold Start