mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

IR DAS 2a Control Module (Up to 6/96)|Page 113 > < Diagram Information and Instructions|Page 107
Page 1
background image

Keyless Entry Module: Description and Operation
IR DAS 2a Control Module (Up to 6/96)

The DAS infrared control module performs the following functions:

a)

Infrared remote central locking

-

Receipt and evaluation of infrared remote control signal

After recognition of valid IR signal

-

Actuation of

-

Central locking (CL)

-

Anti-theft alarm (ATA)

-

Convenience feature (CF)

-

Confirmation on interior rearview mirror

-

Confirmation via turn signals (models 170/202/210 via additional relay)

-

Reading in and evaluating the mechanical lock switches (SN1-unlock, SN2-lock), (only (USA) (J))

b)

Drive authorization system stage 2a (DAS2a)

-

Actuation of transponder coil on ignition/starter switch

-

Reading and evaluating transponder signal

-

Release of engine control module via CAN with valid transponder code

The DAS infrared control module (N54/1) evaluates the transponder data transferred and, if valid, releases the engine control via the CAN data bus.

IR DAS 2a Control Module (Up to 6/96)|Page 113 > < Diagram Information and Instructions|Page 107