E 500 (211.070) V8-5.0L (113.967) (2004)
16.
Close the (gray) secondary lock of the SBC connector housing (A, Figure 18) by sliding the lock in the direction indicated by the arrows (Figure
18) using a small screwdriver until it locks into place.
17.
Reinstall connector cover (A, Figure 13) in reverse order.
18.
Secure SBC wiring harness (A, Figure 19) (excluding ground wires) to the SBC connector cover receptacle (arrow) using a new cable tie (B).
Note:
^
Ensure that the SBC wiring harness (A) is properly routed so that it is free of tension in the SBC connector housing.