E 500 (211.070) V8-5.0L (113.967) (2004)
9.
Remove SBC ground wires (arrows, Figure 11) from SBC harness connector (A):
^
Unpin ground wire connectors (position 37 and 44, Figure 11) using cable release tool and remove from SBC connector housing (A) (special tool
nos.: W 000 589 13 99 30 and W 220 589 01 99 50).
^
Discard old ground wire harness (arrows), it is no longer needed.
10.
Insert the new ground wire harness (arrows Figure 11) into the SBC connector housing (A):
^
Insert longer ground wire into position 44. Insert shorter ground wire into position 37.
Note:
Ensure ground wire connectors are properly locked into place.