E 500 (211.070) V8-5.0L (113.967) (2004)
Component Identification
R lock, function
Above a ground speed of approx. 8 km/h the
R/P locking solenoid (89) is actuated by the electronic selector lever module control unit (N15/5). The rocker arm (102) presses on the rocker (100),
which is turned to the locking position.
The lock lever (69) rests against the rocker (100) and the selector lever (80) cannot be shifted to position "R".
Component Identification
P lock, function
The selector lever position "P" is locked whenever the