Component Identification

Heater operation front and mixed air operation rear; recirculated air mode without activated charcoal filter

Function

In "heating mode at the front and blend air mode at the rear; recirculated air mode without activated charcoal filter" recirculated air (A) is drawn in by
the blower motor (A32m1) due to the position of the actuator motor for fresh air flaps and recirculated air flaps (M2/5). There circulated air (A) is led
past the two activated charcoal filters (2) due to the position of the activated charcoal filter flap adjustment motor (A32m2) and reaches the cooled
evaporator (3), is dried and cooled there. Then the dried and cooled air (B) is heated up again due to the position of the left blending air flap actuator
motor (M2/6) and right blending air flap actuator motor (M2/7) in the heated heater heat exchanger (4) and heater booster (R22/3). Part of the heated air
(C) is led to the air outlets (9, 10, 12) due to the position of the actuator motors (M2/6, M2/7, M2/8, M2/9, M2/10, M2/11).

In addition directly downstream of the evaporator (3) cooled air (B) is diverted which is mixed with the heated air (C) via the position of the left center
air outlet flap actuator motor (M2/12) and the right center air outlet flap actuator motor (M2/13). As a result blend air (D) escapes from the front center
nozzle air outlet (11). Due to the position of the left rear blend air flap actuator motor (M16/30) and the right rear blend air flap actuator motor (M16/31)
the other part of the heated air (C) is mixed with the dried and cooled air (B) which is led past the heat exchanger (4) and heater booster (R22/3). This
mixed air (D) is routed through the positions of the actuator motors (M2/10, M2/11, M16/30 and M16/31) to the air outlets (6, 7, 8) . The condensation
is passed to atmosphere through the condensation drain.

GF83.40-P-2170TT Convenience Automatic Air Conditioning Housing,
Location/Task/Design/Function

GF83.40-P-2170TT Convenience Automatic Air Conditioning Housing, Location/task/design/function

- with CODE (581b) Convenience automatic air conditioning

GF83.40-P-2105-02T Automatic Air Conditioning Box, Function|Page 17649 > < GF83.40-P-2105-02T Automatic Air Conditioning Box, Function|Page 17647