mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

A/C - Blower Motor Inoperative/DTC 09460 Set|Page 986 > < Engine - Oil Level Message General Information|Page 976
Page 1
background image

Blower Motor Relay: All Technical Service Bulletins
A/C - Blower Motor Inoperative/DTC 09460 Set

Date: September 28, 2007

Order No.: P-B-83.25/76c

Supersedes: P-B-83.25/76b dated March 9, 2007

Group: 83

Revision History

Revision

Date

Purpose

C

9/28/07

Work Instructions, Part Number 
and Warranty Information Updated

b

3/9/07

Applicable Models and Content Updated

a

9/20/06

Addition of Note Pertaining to DTC Code 9460

-

1/10/06

Initial issue

SUBJECT: All 171, 203, 209, 211, 219 and 230 Models 

Heater Blower Motor Stops Running

If you receive customer reports in the above model vehicles that the heater blower motor stops running, the blower motor regulator should be replaced.
The related symptoms for this condition are as follows:

1.

During high blower demand, such as defrost or maximum cooling, the blower starts up and shuts off for approximately 90 seconds. The blower
tries to restart and may shut off again. This cycle may repeat.

2.

Manual adjustment of the blower speed and the blower shuts off for 60 seconds and then restarts.

3.

Once the blower has shut off by itself, cycling the ignition off and back on may allow the blower to operate again.

4.

Diagnostic fault code DTC 9460 may be present.

These conditions may be caused by a high blower output requested by the climate system and the blower regulator overload protection engaging
unnecessarily. Follow the procedures below for corrective actions.

1.

Replace the blower regulator as per the WIS document shown.

A/C - Blower Motor Inoperative/DTC 09460 Set|Page 986 > < Engine - Oil Level Message General Information|Page 976