Air Door Actuator / Motor: Description and Operation

GF83.40-P-2182-01T Actuator Motor, Automatic Air Conditioning, Task

GF83.40-P-2182-01T Actuator Motor, Automatic Air Conditioning, Task

- except CODE (581b) Convenience automatic air conditioning

General determinations on actuator motor and flap controls

Continuous positioning of the flaps.
So that the actuator motors do not run continuously in the control range, the following release function is implemented in the automatic air conditioning
system for every flap.
Clearance function: Once a position has been set, the specified blower air temperature for example must change sufficiently by the next change for the
clearance value above or below it to be undershot or overshot.
Final values are approached directly (0 %, 100 %).

Anti-fogging function

The anti-fogging function prevents the windshield and side windows from becoming fogged up after starting the engine thank to the fact that moist air is
not guided directly against the windows after starting, but instead into the footwell of the vehicle.

Solar roof function (on model 211.0 with code (419) solar module for panoramic roof)

'The actuator motors are driven to the following position after 2 minutes and outside temperatures greater 10 °C:

-

center nozzle 100 % open

-

activated charcoal filter flap OFF (fresh air)

Afterwards the AAC control and operating module (N22) shuts down.

For

-

automatic and manual flap operation

-

with ignition OFF or REST OFF or stationary heater OFF

the following procedure applies:
The actuator motors are driven into the following positions after 2 minutes:

-

footwell flaps open

-

defroster flaps closed

-

recirculated air flap closed

-

center air outlet stops in the last valid setting.

For
Ignition ON:

up to 30 seconds after engine ON

REST ON:

60 seconds starting with the request

Stationary heater ON:

60 seconds starting with the request

the following procedure applies:

-

footwell flaps open

-

defroster flaps closed

-

center nozzle automatic according to specification

-

recirculated air flap immediately operable (including automatic recirculated air)

After these times have elapsed, the flap states for the automatic or manual setting apply

Center outlet flap actuator motor (M2/22)

The center outlet flap actuator motor (M2/22) actuates the air flaps for controlling the air flow to the center nozzles.
Depending upon the desired air outlet temperature at the center nozzle, the center outlet flap actuator motor (M2/22) is actuated via the AAC control and
operating module (N22) and the AC bus.

Actuation at "defrost"

footwell flaps 0 % (closed)

Actuation with "REST"

according to regulation

Actuation with stationary

heater as per the control (if fitted)

Actuation at "0"

previous position retained

Actuation with ignition OFF

previous position retained

Automatic air flap control