mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

AR41.10-P-0086CW Measure Propeller Shaft Alignment With Electronic Propeller Shaft Inclinometer|Page 5113 > < AR41.10-P-0086CW Measure Propeller Shaft Alignment With Electronic Propeller Shaft Inclinometer|Page 5111
Page 2
background image

Confirmation Screen

A confirmation message appears briefly.

Confirmation screen

Ready Screen For Angle 3

The meter then indicates that it is ready to measure the next angle (angle 3).

4

Remove sensor (020a) from front propeller shaft (1).

Ready screen for angle 3

Measurement - Angle 3: rear propeller shaft

Component Identification

5

Clean contact surfaces for sensor (020a) on rear propeller shaft (2).

6

Position sensor (020a) horizontally on rear propeller shaft (2) and press on firmly.

The spiral cable (020b) of the sensor (020a) must point in the direction of travel for each measurement. Otherwise the measurement will be
inaccurate. If the sensor (020a) is not positioned horizontally on the rear propeller shaft (2), the error message "Y-positional error - sensor ??"
appears on the display. The measured angle cannot be saved.

AR41.10-P-0086CW Measure Propeller Shaft Alignment With Electronic Propeller Shaft Inclinometer|Page 5113 > < AR41.10-P-0086CW Measure Propeller Shaft Alignment With Electronic Propeller Shaft Inclinometer|Page 5111