AR40.20-P-0322-03GZA Check Caster and Assign to Tabular Value

AR40.20-P-0322-03GZA Check caster and assign to tabular value

- except CODE (430) Offroad package

The caster is measured between a 20 degrees wheel angle to the right and a 20 degrees wheel angle to the left, and varies according to the vehicle
level. Different vehicle levels therefore make it necessary to determine the specified caster value based on a caster table as follows:
^

Determine level of front axle and level of rear axle using the electronic inclinometer.

The level value is displayed by the electronic level gauge in decimal degrees only (Romess value). The details given in millimeters in the caster
table only serve for a better understanding.

The tolerance is ± 30'.

Maximum caster difference between left and right is 0 degrees 30'.

Example:
Level at front axle (VA): 9.0 degrees (value on inclinometer)
Level at rear axle (HA): 3.2 degrees (value on inclinometer)
Specified caster value: 5 degrees 28' (determined from the caster table)