The function requirements for this switch is circuit 15R "ON".

Hazard warning system switch

Pressing the hazard warning system switch wakes-up the upper control panel control unit from its "Sleep mode" and the hazard warning system function
is activated. The message is sent cyclically (every 100 ms) until the function is deactivated by pressing the hazard warning system switch again. The
flashing function illumination of the hazard warning system switch is triggered by the CAN message of the rear SAM control unit (N10/8). There is no
faster flashing of a defective indicator lamp for the hazard warning flasher system. As soon as the hazard warning flasher function is activated the switch
and controls illumination for the hazard warning system switch is switched off. The function illumination of the hazard warning system is not dimmed.

The selected function is confirmed when the indicator lamps (LEDs) light up. The pulse to light up is sent by each respective control unit.

STH switch

The function of the STH switch depends on the current terminal status. Whenever the stationary heater is activated, the AAC [KLA] control and
operating unit (N22) receives a query as to whether heating or ventilation is required. The currently active function is displayed by an indicator lamp in
the STH switch as follows:

-

Indicator lamp red: Heating mode

-

Indicator lamp blue: Ventilation mode

-

Indicator lamp yellow: Activation of stationary heater via timer

Function with terminal 15R OFF

If the switch is actuated, the system is switched on or off immediately. When switched on, the upper control panel control unit sends a signal to the heater
booster control unit (N33/2). The latter then sends the command to switch on the stationary heater to the AAC [KLA] control and operating unit.

Since the AAC [KLA] control and operating unit needs time to decide whether heating or ventilation is required, the red indicator lamp is activated by
the upper control panel control unit immediately after the switch is actuated.

The AAC [KLA] control and operating unit permanently switches the indicator lamp to the appropriate color depending on whether heating or
ventilation is required.

Function with terminal 15R ON

If the switch is actuated for less than 2 s with the system switched off, the timer menu is shown in the multifunction display (A1p13) in the instrument
cluster. The system will be activated if the switch is pressed for a longer time.

If the system is already activated, it is switched off again immediately without the timer menu being displayed.

Discrete inputs:

-

Circuit 30

-

Circuit 31

-

CAN-B

Discrete outputs:

-

Circuit 30

-

Circuit 31

-

LIN bus

Voltage limit: The operating voltage is between 12 and 14 V.

GF54.21-P-6040GZU Upper Control Panel Control Module Component Description

GF54.21-P-6040GZU Upper Control Panel Control Module Component Description

-

with CODE (489) Airmatic (air suspension with level adjustment and adaptive damping system ADS)

-

with CODE (430) Offroad package

-

with CODE (494) USA version

GF54.21-P-6040GZ Upper Control Panel Control Module Component Description|Page 12069 > < GF54.21-P-6040GZ Upper Control Panel Control Module Component Description|Page 12067