background image

function requirements for this switch is circuit 15R "ON". Each press of the left front HS [SIH] switch and right front HS [SIH] switch is sent by the
upper control panel control unit over the CAN-B.

Comfort/Sport switch (ADS)

The driver can program the damping level as desired using the Comfort/ Sport switch (ADS):

1. "AUTO"

Skyhook mode

2. "SPORT"

Firm damping

3. "COMFORT"

Soft damping

In the "SPORT" setting the upper LED goes on and for the "COMFORT" setting the lower LED goes on. If the vehicle is in the "AUTO" mode nothing
is displayed in the Comfort/Sport switch (ADS).

Transmission mode switch

Pressing the transmission mode switch enables the driver to choose between a comfort-oriented and a sporty transmission program. The transmission
mode switch is read in by the upper control panel control unit and sent to the CAN-B. The central gateway control unit (N93) reads in this message and
then sends it over the CAN-C to the fully integrated transmission control (VGS) control unit (Y3/8n4). Each respective transmission program is selected
in the fully integrated transmission control (VGS) control unit. The function requirements for this switch is circuit 15R "ON".

Hazard warning system switch

Pressing the hazard warning system switch wakes-up the upper control panel control unit from its "Sleep mode" and the hazard warning system function
is activated. The message is sent cyclically (every 100 ms) until the function is deactivated by pressing the hazard warning system switch again. The
flashing function illumination of the hazard warning system switch is triggered by the CAN message of the rear SAM control unit (N10/8). There is no
faster flashing of a defective indicator lamp for the hazard warning flasher system. As soon as the hazard warning flasher function is activated the switch
and controls illumination for the hazard warning system switch is switched off. The function illumination of the hazard warning system is not dimmed.

The selected function is confirmed when the indicator lamps (LEDs) light up. The pulse to light up is sent by each respective control unit.

Discrete inputs:

-

Circuit 30

-

Circuit 31

-

CAN-B

Discrete outputs:

-

Circuit 30

-

Circuit 31

-

LIN bus

Voltage limit: The operating voltage is between 12 and 14 V.

GF54.21-P-6060GZ Lower Control Panel Control Unit, Component Description

GF54.21-P-6060GZ Lower Control Panel Control Unit, Component Description

-

with CODE (489) Airmatic (air suspension with level adjustment and adaptive damping system ADS)

-

with CODE (430) Offroad package

GF54.21-P-6040GZ Upper Control Panel Control Module Component Description|Page 6128 > < GF54.21-P-6040GZ Upper Control Panel Control Module Component Description|Page 6126