mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Procedures|Page 7424 > < Procedures|Page 7422
Page 5
background image

Component Identification

1

Position adapter for transmission (8a) at flange of front axle gear (11) and move into the horizontal position using the spirit level.

Check the seat of the magnetic fork on the flange of the front axle gear (11).

If the location of the sensor (086a) deviates excessively from the horizontal, an error message appears on the display of the measuring instrument,
no value can be read off or stored.

2

Place sensor (086a) on the support plate.

The cable (10) must point forwards (arrow), otherwise an incorrect measurement occurs.

Ensure that the sensor (086a) is seated correctly in the bores of the support plate, otherwise an incorrect measurement occurs.

3.1

Read off the absolute angle on the flange of the front axle gear (1) on the display of the measuring instrument and enter in the data sheet.

If the electronic inclinometer is used or if a measurement is made with the electronic propeller shaft inclinometer in inclination measuring
mode.

The X-value of the display must be read off. Otherwise incorrect results occur.

The measured value must not be stored.

The absolute angle at the flange of the front axle gear may only be read off if the sensor (086a) on standby and the displayed value is constant.

3.2

Store absolute angle at flange of front axle gear (1) in measuring instrument.

If the electronic propeller shaft inclinometer with memory extension is used or the electronic inclination propeller shaft inclinometer with
memory extension is used in articulation angle measuring mode.

Store the measured value by pressing the SAVE button. Afterwards the measurement readiness for the second angle is displayed.

The absolute angle at the flange of the front axle gear (1) may only be stored if the sensor (086a) on standby and the displayed value is
constant.

AR41.10-P-0085-08GZ Measure Absolute Angle of Front Propeller Shaft

Procedures|Page 7424 > < Procedures|Page 7422