mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF83.20-P-0002GH Heater Function|Page 9982 > < GF83.20-P-2103-01GH Heater Housing Position|Page 9979
Page 1
background image

Housing Assembly HVAC: Description and Operation
GF83.20-P-0002GH Heater Function

GF83.20-P-0002GH Heater Function

Function

The heater enables a pleasant interior climate for the vehicle passengers in the event of different weather conditions.

A nominal temperature is preset at the heater pushbutton control module temperature selector wheel. This setting is transmitted to the blending air flaps
in the heater housing via a cable and an actuation mechanism. Control is then carried out there as follows:

Temperature selector wheel MAX setting (full heater output)

Due to the setting of the blending air flaps, the drawn in air is routed through the heat exchanger. Heated cooling water generally flows through this, as a
result of which the passing air is heated. The temperature-controlled air is guided into the vehicle interior via the various air outlets.

Temperature selector wheel MIN setting (no heater output)

In this setting, the blending air flaps block the route to the heat exchanger. The drawn in fresh air is guided directly to the air outlets and therefore into
the vehicle interior.

GF83.20-P-0002GH Heater Function|Page 9982 > < GF83.20-P-2103-01GH Heater Housing Position|Page 9979