mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

A/C - Insufficient Cooling When Idling|Page 9934 > < GF83.40-P-2120-02GH Condenser, Location|Page 9925
Page 1
background image

Condenser Fan: All Technical Service Bulletins
A/C  - Insufficient Cooling When Idling

Date: July 26, 2004

Order No.: T-B-83.30/62a

Supersedes: T-83.30/62 dated Sept. 3, 2002

Group: 83

Revision: Applicable VIN Range Extended

SUBJECT:
Model 163.154/172 up to A289564 

Insufficient Air Conditioning When Idling

If you receive customer reports in the above models where the air conditioning is insufficient when idling, please perform the following procedure.

1)

Inspect fuse f44, replace if blown.

Note

Fuse f44 may blow due to excessive cycling of auxiliary fan.

2)

Check auxiliary fan operation.

Note

If auxiliary fan does not operate, perform the corresponding diagnosis and repair. If the fan does not operate satisfactorily, check whether the
auxiliary wiring harness (Figure 1, 2) for the auxiliary fan has already been installed. The original auxiliary fan connector (M4x1) is already fastened
next to the new auxiliary fan connector (Figure 1, 3) with adhesive tape. If auxiliary wiring harness (Figure 1, 2) is already installed, ensure that a 40
Amp fuse in located at position f44. If an auxiliary wiring harness (Figure 1, 2) has not yet been installed, install the auxiliary wiring harness as
follows.

3)

Disconnect the battery's ground cable. Refer to WIS documents AR54.10-P-0003A and BA54.10-P-1001-01A.

4)

Remove rear cover (5 screws) from fuse and relay module (Figure 1, F1).

5)

Remove the mounting screws of the fuse holder on the fuse and relay module (Figure 1, F1) and lay down to side.

6)

Disconnect the blue connector (Figure 1, ML/B) from the bottom of the fuse holder.