mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Models With Touch Shift|Page 7069 > < Models With Touch Shift|Page 7067
Page 6
background image

transmission range recognition switch (S16/10) in the floor shift. If the selector lever is moved across from "D" to "4", the selector lever is isolated
from the shift rod. Thus there is no longer any mechanical connection with the transmission. The selector lever positions "4", "3", "2" and "1" are then
transmitted electronically to the ETC control module (N15/3) via the transmission range recognition switch.

Related Information

Shift Detent

Location/Task/Design/Function

Component Illustration

Location

The shift detent is integrated into the floor shift.

Task

Fixes the selector lever positions 4, 3, 2 and 1.

Design 

The shift detent consists of a detent (67a) containing a spring loaded ball and the shift gate (67b) with 4 recesses arranged one under another.

Function 

When the selector lever is moved between the positions 4, 3, 2 and 1, the shift detent (67a) engages in one of the 4 recesses in the shift gate (67b).

Related Information

R/P Lock

Location/Task/Design/Function

Models With Touch Shift|Page 7069 > < Models With Touch Shift|Page 7067