mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Trip Computer (TRIP), Function|Page 11545 > < Trip Computer (TRIP), Function|Page 11543
Page 12
background image

continue running. (At the same time the trip computer must be in travel time operating mode).

-

The travel time stops when the starter switch is in position "0". The value displayed last is retained in the memory. If starter switch (S2) is turned
back to position "1", the travel time continues to run starting from the stored value. There is no automatic reset.

-

Reset
If the display is set to 00:00 (Reset), the reset button should be held down for 2 seconds Then press the reset button again to start a new interval.
(Spalte 2)

-

Low voltage
After a low voltage, e.g. after the battery has been disconnected, the display reads 00:00.

GF54.50-P-2005GH Momentary and Average Fuel Consumption, Function

GF54.50-P-2005GH Momentary And Average Fuel Consumption, Function

-

with CODE (245) Trip computer

Momentary fuel consumption

The momentary fuel consumption is displayed in either

-

miles per gallon (Fig. 1) (the possible range is 99.9 (previously 70) mi/gal to 0 mi/gal), or in

-

l/100 km (Fig. 2) (the possible range is 0 l/100 km to 36 (previously 99.9) l/100 km).

The current fuel consumption is calculated from the distance traveled in a second and the quantity of fuel used during this second. The value is updated
every second.

When the engine is running and the vehicle is stationary, the maximum value (0 mi/gal or) 36 (previously 99.9) l/100 km) is displayed. When the vehicle
is decelerating (inertia fuel shutoff) at rotational speeds of approx. 2000 rpm, the minimum value is displayed.

Average fuel consumption

Trip Computer (TRIP), Function|Page 11545 > < Trip Computer (TRIP), Function|Page 11543