mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Air Door Actuator / Motor, HVAC|Service and Repair > < Blend Air Flap Actuator Motor, Purpose|Page 9614
Page 9
background image

-

temperatures of the air stream measured at the center nozzle air stream temperature sensors, footwell forward and rear (B10/24, B10/25 and
B10/7)

-

outside temperature measured by the outside temperature indicator temperature sensor (B14)

All actuators are identical.

If a problem exists, it is possible to retrieve and verify the defined end positions by means of the diagnosis assistant system (DAS) (valuation trip).

After an actuator motor has been replaced, an adjustment run must be performed via the Diagnosis Assistant System (DAS), i.e. the end positions flap
OPEN and SHUT are defined and retained.

GF83.57-P-2112GC Blending Air Flap Actuator Motor, Location/Task/Function

GF83.57-P-2112GC Blending Air Flap Actuator Motor, Location/Task/Function

-

with CODE (580) Air conditioning or Tempmatic for USA

GF83.57-P-2112GI Blending Air Flap Actuator Motor, Location/Task/Function

GF83.57-P-2112GI Blending Air Flap Actuator Motor, Location/Task/Function

-

with CODE (580a) Automatic air conditioning

Air Door Actuator / Motor, HVAC|Service and Repair > < Blend Air Flap Actuator Motor, Purpose|Page 9614