ML 55 AMG (163.174) V8-5.5L (113.981) (2001)
Component Illustration
Location
In the valve housing of the shift plate.
Task
Regulates the shift pressure (p-S).
Function
The shift pressure is determined by the shift pressure regulating solenoid valve (Y3/6y2) and the shift pressure regulating valve (24). In addition,
pressure from the clutch K2 (p-K2) is also present at the annular surface (24a) of the shift pressure regulating valve (24). This reduces the shift
pressure in 2nd gear.
Related Information
Regulating Valve Pressure Regulating Valve
Location/Task/Function
Component Illustration
Location
In the valve housing of the electrohydraulic control module.
Task
Regulates the regulating valve pressure (p-RV).
Function
The regulating valve pressure (p-RV) is set at the regulating valve pressure regulating valve (20) in relation to the working pressure (p-A) as far as the
maximum pressure.
Related Information
Shift Valve Pressure Regulating Valve
Location/Task/Function