mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Air Door Actuator / Motor, HVAC|Service and Repair > < GF83.10-P-2201GZ Actuator Motors, Component Description|Page 13224
Page 3
background image

7 o'clock

8 o'clock

9 o'clock

10 o'clock 11 o'clock 12 o'clock

54%

30 %

0 %

0 %

0 %

0 %

Automatic footwell flap control

The footwell flaps are opened in line with the following variables linear up to 100 %:

^

Blending air flap setting

^

Coolant temperature

^

Evaporator temperature

Fresh air/air recirculation flaps actuator motor

The fresh air/air recirculation flaps actuator motor is used to close or open the fresh air supply by actuating the fresh air/air recirculation flaps.
The fresh air/air recirculation flaps actuator motor is actuated by pressing the air recirculation switch (N22/7s2) on the comfort AAC control and
operating unit.
In recirculation mode, the recirculation flap is open and the fresh air flap is closed.
Air is suctioned from the vehicle interior into the comfort automatic air conditioning housing by the blower.
In fresh air mode, the fresh air flap is open and the recirculated air flap is closed. Fresh air is suctioned into the comfort automatic air conditioning
housing by the blower.

If the air recirculation switch is operated manually, the system immediately enters time-limited 100 % recirculated air. This is displayed by the function
LED. Time limit function:

^

after 30 min with outside temperature above approx. 7 °C,

^

after 5 min with outside temperature below approx. 7 °C,

^

after 5 min with AC OFF.

100 % automatic recirculated air is possible for one time only for 30 min after ignition is switched "ON". After the time has elapsed, the system switches
to 80 % recirculated air mode or fresh air mode, depending on the conditions.
If automatic recirculated air is required after engine ON, fresh air will be circulated initially for 30 seconds. Then 80 % automatic recirculated air is
supplied first and 10 s later as required also 100 % automatic recirculated air.

Tunnel function
Activation of the tunnel function:

Only possible where the recirculated air LED is not illuminated. Pressing the air recirculation switch for more than 1.5 s
Reaction: fresh air and air recirculation flaps are driven into air recirculation position. Now the 4 windows and the tilting/sliding roof are closed in a
staggered manner.
If the recirculated air-LED is extinguished manually or by the automatic timer, the fresh air and air recirculation flap moves to the fresh air position,
however, the windows and the sliding roof remain closed.

Deactivation of tunnel function:

Only possible where the recirculated air LED is illuminated. Pressing the air recirculation switch for more than 1.5 s

Reaction: fresh air and air recirculation flaps are driven into fresh air position. Now the 4 windows and the tilting/sliding roof are opened in a staggered
manner.

If the recirculated air LED is reset to manual mode (pressing the air recirculation switch for less than 1.5 s), only the fresh air/air recirculation flap is set
to recirculated air position.

Special functions of the fresh air/air recirculation control:

^

The function AC OFF does not allow any automatic nor emissions-controlled recirculated air.

^

Only fresh air mode is possible in the defrosting function.

^

In the function "0" 100 % recirculated air applies.

^

Manual recirculated air is deleted after ignition OFF.

^

No manual or automatic recirculated air is possible in the rest function.