Intake solenoid valves

The inlet solenoid valves are opened during the ASR/ESP pressure buildup phases, if the calculated pressures in the respective brake caliper are <= 60
bar and one of the following valves is actuated:
^

Left front solenoid valve (pressure hold),

^

Right front solenoid valve (pressure hold),

^

Left rear solenoid valve (pressure hold) or

^

Right rear solenoid valve (pressure hold)

If the calculated pressures are > 60 bar the following remain open even during the ASR/ESP holding phases
^

Pressure circuit 1 inlet solenoid valve and

^

Pressure circuit 2 inlet solenoid valve