mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF83.10-P-2201RT Actuator Motors, Component Description|Page 14828 > < GF83.10-P-2201RT Actuator Motors, Component Description|Page 14826
Page 3
background image

^

Relative humidity

Left footwell flap actuator motor and right footwell flap actuator motor

The left footwell flap actuator motor and the right footwell flap actuator motor operate the particular footwell flap that controls the air flow to the front
footwell and the rear legroom separately for each side.
By pressing the footwell air distribution button in the comfort AAC control and operating unit, the left footwell flap actuator motor and the right footwell
flap actuator motor are actuated. The footwell flaps adopt the following positions at various requirements:

Actuation for "Defrost" Footwell flaps 0 % (closed)
Actuation for "Rest"

according to control

Actuation for "0"

no change

Manual flap control
(division as clock by actuating the air distribution wheel)

1 o'clock

2 o'clock

3 o'clock

4 o'clock

5 o'clock

6 o'clock

29%

72 %

100 %

100 %

100 %

100 %

7o'clock

8 o'clock

9 o'clock

10 o'clock 11 o'clock 12 o'clock

54%

30 %

0 %

0 %

0 %

0 %

Automatic footwell flap control

The footwell flaps are opened linearly up to 100 %, depending on the following values:

^

Blending air flap setting

^

Coolant temperature

^

Evaporator temperature

Fresh air/air recirculation flaps actuator motor

The fresh air/air recirculation flaps actuator motor is used to close or open the fresh air supply by actuating the fresh air/air recirculation flaps.
The fresh air/air recirculation flaps actuator motor is actuated by pressing the air recirculation switch (N22/7s2) on the comfort AAC control and
operating unit.
In air recirculation mode, the recirculation flap is open and the fresh air flap is closed.
Air is suctioned from the vehicle interior into the comfort automatic air conditioning housing by the blower.

In fresh air mode, the fresh air flap is opened and the recirculated air flap is closed. Fresh air is suctioned into the comfort automatic air conditioning
housing by the blower.

If the air recirculation switch is operated manually, the system immediately enters time-limited 100 % recirculated air. This is displayed by the function
LED. Time limit function:

^

after 30 min at outdoor temperatures above approx. 7 °C,

^

after 5 min at outside temperatures below approx. 7 °C,

^

after 5 min following AC OFF.

100 % automatic recirculated air is possible for one time only for 30 min after ignition is switched "ON". After the time has elapsed, the system switches
to 80 % recirculated air mode or fresh air mode, depending on the conditions.
If automatic recirculated air is required after engine ON, fresh air will be circulated initially for 30 seconds. Then, operation is first continued
automatically with 80 % recirculated air and 10 s later, also with 100 % automatically recirculated air, depending on the requirement.

Tunnel function
Activation of the tunnel function:

Only possible where the recirculated air LED is not illuminated. Actuation of the air recirculation switch for longer than 1.5 s Reaction: fresh air and air
recirculation flaps are driven into air recirculation position. Now the 4 windows and the tilting/sliding roof are closed in a staggered manner.
If the recirculated air LED is extinguished manually or by the automatic timer, the fresh air and air recirculation flap moves to the fresh air position,
however, the windows and the sliding roof remain closed.

Deactivation of tunnel function:

Only possible where the recirculated air LED is illuminated. Actuation of the air recirculation switch for longer than 1.5 s Reaction: Fresh air and air
recirculation flaps are driven into fresh air position. Now the 4 windows and the tilting/sliding roof are opened in a staggered manner.

If the recirculated air LED is reset to manual mode (pressing the air recirculation switch for less than 1.5 s), only the fresh air/air recirculation flap is set
to recirculated air position.

GF83.10-P-2201RT Actuator Motors, Component Description|Page 14828 > < GF83.10-P-2201RT Actuator Motors, Component Description|Page 14826