S 350 (140.134) L6-3.5L DSL Turbo (603.971) (1995)
NOTE: If one or more pneumatic circuits of the CA supply pump are switched off by the safety feature (incorrect pressure buildup times), the pump can
be reset by briefly interrupting circuit 30. This can be done by removing fuse F4-9 in rear fuse box F4 for approx. 5 seconds or by disconnecting the
connector from the CA supply pump (M14/3).
Special Tools
NOTE: Any suitable pressure gauge which reads in bar (range 1 to 5 bar) can also be used.
Conventional Tools, Test Equipment
Description
Brand, model, etc:
Engine analyzer 1)
Bear DACE (Model 40-960)
Sun MEA-1500MB
1) Available through the MBNA Standard Equipment Program.
Parts Required for Test
Connections