Vacuum Pump: Procedures

Double Diaphragm

Disassembly

1. Clamp vacuum pump in a suitable soft jaw vise.
2. Remove pump closing cover attaching screws and cover.
3. Remove compression springs, plate valves and seals from pump.
4. Remove pump cover attaching screws and cover.
5. Remove diaphragm rod attaching screw, then diaphragm with discs and seals.

Assembly

1. Remove all grease from threads in diaphragm rod, then install new O-ring.
2. Install diaphragm with new discs onto diaphragm rod. Install lower disc with beaded edge down, diaphragm with lettered or raised portion

up and upper disc with beaded edge up.

3. Apply suitable locking compound to diaphragm screw, then install screw and torque to 7 ft. lbs., while preventing disc from turning.
4. Install new check valve and seals into pump housing.
5. Position pump cover on housing, then install cover screws and turn in 2-3 threads.
6. Position valve seals into valve housing.
7. Install vacuum pump adapter cover (part No. 617589036300) to vacuum pump and attach vacuum hose to adapter.
8. Apply hand pressure to upper corners of vacuum pump cover, then apply a minimum of 14.8 inches Hg vacuum to vacuum pump using a hand

pump attached to hose on adapter.

9. If vacuum pump holds vacuum with no leakage, torque pump cover screws to 4 ft. lbs.

10. Remove adapter cover from vacuum pump, then install plate valves into valve seats.
11. Install compression springs, then pump closing cover using a new gasket. Torque closing cover attaching screws to 2 ft. lbs.

Single Diaphragm

Disassembly

1. Secure vacuum pump in special holding fixture tool 115589142100, or equivalent, with fixture spindle completely backed out. Casting seam on

vacuum pump must be centered between two forward screws of holding fixture.

2. Turn holding fixture spindle up to stop to preload diaphragm.
3. Remove vacuum pump closing cover attaching screws and cover.
4. Remove compression springs and plate valves from pump housing.
5. Mark relationship between pump cover and housing for Assemble reference, then remove cover attaching screws and cover.
6. Remove diaphragm attaching screw from rod, then diaphragm and two discs.
7. Back off holding fixture spindle to relieve spring pressure, then remove vacuum pump from holding fixture.
8. Remove upper spring retainer and two compression springs from diaphragm rod.
9. Remove rocker arm shaft plug from housing, then remove shaft, rocker arm and diaphragm rod from pump housing.

10. Remove diaphragm rod guide bushing, then lower spring retainer.

Assembly

1. Position lower spring retainer on diaphragm rod, then press on guide bushing.
2. Secure diaphragm rod to rocker arm with bearing bolt, then install locking rings.
3. Install upper spring retainer and two compression springs into pump housing.
4. Position diaphragm rod with lower spring retainer, then install rocker arm and mount shaft.
5. Install rocker arm shaft into housing.
6. Secure vacuum pump in holding fixture and preload diaphragm rod by turning holding fixture spindle to stop so dimension "a,"equals

approximately 1.02 inch.

7. Remove all grease from threads in diaphragm rod.
8. Position large diaphragm plate, with both blind holes downward, on diaphragm rod.
9. Install diaphragm, with raised or lettered portion facing up, then smaller diaphragm plate.

10. Apply suitable locking compound to diaphragm rod screw, then install screw with copper sealing ring. Torque screw to 7 ft. lbs. while holding

diaphragm with a suitable tool.

11. Install pump cover, referring to marks made during disassemble, and torque attaching screws to 4 ft. lbs.
12. Install seals and plate valves into valve seats.
13. Install compression springs, then pump closing cover with new gasket.

Piston

1. Secure vacuum pump in special holding fixture tool 115589142100, or equivalent, with fixture spindle completely backed out. Casting seam on

vacuum pump must be centered between two forward screws of holding fixture.

2. Move piston rod and piston to TDC position by turning holding fixture spindle up to stop.
3. Remove pump cover attaching screws and cover.
4. Remove pump cover gasket, then gaskets and plate valves from housing.
5. Remove locknut and washer from piston rod.

Procedures|Page 4121 > < Double Diaphragm|Page 4118