S 350 (140.134) L6-3.5L DSL Turbo (603.971) (1995)
3.
Apply sealant/locker to fitting (arrow, Figure 13) and tap it into the lower vent bore of the coolant pump with a suitable mandrel.
4.
Push the drainage pipe over the fitting.
5.
Attach the drainage pipe (1, Figure 14) with the clamp (2) to the generator/fan bracket (4) with M8 x 16 bolt (3).
Tightening torque:
M8 x 16 generator/fan bracket bolt 22 Nm
6.
Attach the drainage pipe (1, Figure 15) at the lower oil pan with the bracket (2) and position correctly.