mercedesbenz Workshop Repair Guides

Mercedes Benz S 350 L6-35L DSL Turbo Workshop Service and Repair Manuals

Symbols Used For Test Equipment and Components|Page 6248 > < Symbols Used For Test Equipment and Components|Page 6246
Page 2
background image

38-pole Data Link connector (X11/4)

Connect Impulse counter scan tool as follows:
-

Red wire (circuit 30, voltage):  socket 3

-

Black wire (circuit 31, ground): socket 1

-

Yellow wire to diagnostic output socket of the system being tested.

Connection Diagram

013 

Impulse counter scan tool

075 

Adaptor for impulse counter scan tool

087 

Hand-Held Tester (HHT)

094 

Multiplexer, 965 589 00 40

X11/4  Data link connector

16-pole Data Link Connector (X11/4)

Connect HHT as follows:
-

Black wire (circuit 31, ground): socket 1

-

White wire (circuit 15, voltage): 

socket 16

-

Red wire (circuit 30): 

Battery + 
or X4/10

-

Yellow wire to diagnostic output socket of the system being tested.

Connect impulse counter scan tool as follows:
-

Black wire (circuit 31, ground): socket 1

-

Red wire (circuit 15, ignition):  socket 16

-

Yellow wire to diagnostic output socket of the system being tested.

Symbols Used For Test Equipment and Components|Page 6248 > < Symbols Used For Test Equipment and Components|Page 6246