S 420 (140.043) V8-4.2L (119.981) (1996)
NOTE: Two stage vacuum actuators function at full stroke (100%) only, if the long stroke (80%) and the short stroke (20%) are pressed.
Pressing the short stroke (20%) by itself does not change the flap position.
The blower motor will operate on 6 V during the test.
0 - 5