S 500 Coupe (140.070) V8-5.0L (119.980) (1997)
Evaporative Shut Valve: Description and Operation
Activated Charcoal Canister Shutoff Valve, Function
Activated Charcoal Canister Shutoff Valve, Function
Shown in the design of model 210
77
Activated charcoal canister
Y58/4
Activated charcoal canister shutoff valve
A
Ventilation via the shutoff valve
B
Ventilation via the safety valve
The activated charcoal canister shutoff valve (Y58/4) is actuated at the ground end by the ME control unit to conduct the leak test of the fuel system. In
case of errors in the shutoff valve (valve does not open) a mechanical safety valve (as of approx. 25 mbar) takes over the aeration of the activated
charcoal canister (77).