Unscrew.

11 clips (94)

Press out and remove frame (90).

Connections M4x1, M4x2 

Unclip.

5 bolts (84)

Unscrew and remove auxiliary fan.

2 bolts (3)

Unscrew and remove condenser from radiator.

Install 

In reverse sequence, lubricating the connection thread with compressor oil (refer to note below).

Receiver dehydrator

Renew. See: Receiver Dryer/Service and Repair

Air conditioner

Evacuate, refill, check function and check for leaks; run engine at idle speed only in the first 4 minutes.

NOTE:  If the condenser is not reinstalled immediately, flush out the condenser with nitrogen. Then seal the connector with plugs. When renewing
the condenser, fill it with 20 cubic cm compressor oil.

NOTE:  Parts which have come into contact with compressor oil for R12 or R134a may only be installed in systems operating with the same 
refrigerant.

Tightening torque

Nm

Line beneath condenser

24 ± 4

Line above condenser

17 ± 3