Control Module HVAC: Description and Operation
Auxiliary Fan Control Module

The auxiliary fan control module switches on the auxiliary fan.

The pushbutton control module controls the AIR control module (N65/1) with a minimum of 3 mA and max. 10 mA.

The AIR control module (N65/1) compares these values with stored values and switches on the auxiliary fan (M4) under the following conditions:

-

Outdoor temperature >5 °C

-

Refrigerant pressure = 13 bar

-

Coolant temperature = 103 °C

-

Limp-home mode (e.g. refrigerant pressure > 20 bar)

The auxiliary fan (M4) is switched off under the following conditions:

-

Refrigerant pressure = 12 bar

-

Coolant temperature = 100 °C