mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

O2 Sensors, Location/Task/Design/Function|Page 3861 > < O2 Sensors, Location/Task/Design/Function|Page 3859
Page 4
background image

Lower limit value for work measurement 

Upper limit value for work measurement 

Duration of sensor state change for lean-rich transition 

Duration of sensor state change for rich-lean transition 

Duration between sensor state change   

Threshold for rich range (e.g. greater than 475 mV) 

Threshold for lean range (e.g. less than 425 mV) 

Time in ms 

Sensor voltage in mV 

Faults at the O2 sensor can be detected by means of the O2 sensor signal. 
Defined limit values must be maintained for the O2 sensor voltage, the duration of the period and for the sensor status change.     

The O2 sensor signal has a steep voltage jump (at lambda=1) at the transition from a rich (A) to a lean mixture (B). This property is utilized for the
lambda closed-loop control. 
 

 
ME-SFI 1.0 
The ground for the sensor signal at the ME 1.0 control unit is raised to approx. +0.71 V compared to the general vehicle ground. In the event of a short
circuit of the sensor signal to ground, the ME control unit thus switches the lambda closed-loop control to open-loop mode (average  value). This
prevents a high fuel consumption. 

ME 2.0, ME 2.1, ME 2.7, ME 2.8 with engine control unit for EURO 3/4

The ground cable for the sensor signal for each O2 sensor is routed up to the ME control unit. 
The ground for the sensor signal is increased to approx. +0.268 V compared to the general vehicle ground e.g. at the ME 2.1 control unit. In the event of
a short circuit of the sensor signal to ground, the ME control unit thus switches the lambda control to open-loop mode (average lambda value). This
prevents a high fuel consumption.   
The analysis circuit for the O2 sensor signal outputs a so-called sensor back voltage of approx. 0.470 V. If the O2 sensor is cold, the sensor internal
resistance is so high that the O2 sensor voltage is initially equal to the backvoltage irrespective of the mixture composition. 
The backvoltage at the ME control unit can be measured to the sensor ground if the O2 sensor is disconnected. 

ME-SFI Lambda Control Function

ME-SFI Lambda Control Function

O2 Sensors, Location/Task/Design/Function|Page 3861 > < O2 Sensors, Location/Task/Design/Function|Page 3859