Connection Diagram

013

Impulse counter scan tool (alternatively: Hand-Held Tester 087)

087 

Hand-Held Tester (HHT) (alternatively: Impulse Counter Scan Tool)

X4/10  Terminal block, circuit 30
X11/4  Data link connector
Adapter cable, 965 589 00 50 00 (not shown)

38-pole Data Link Connector (X11/4)

1. Connect HHT with Multiplexer (094) attached to Data link connector X11/4
2. Turn Ignition: ON
3. According to instructions in HHT display:

a) Readout DTC memory/erase
b) Readout Actual values
c) Perform Activations
d) Program control modules

4. Disconnect HHT.

NOTE:  
-

Observe all system specific instructions listed in the "Preparation for Test" section of each Test Program.

-

Diagnostic trouble codes (DTC's) which have been stored due to testing or the disconnection of lines must be erased from the diagnostic trouble
code memory at the end of testing.