Battery: Service and Repair
Disconnecting and Connecting Battery

NOTE:  Observe warning information and safety regulations, See: Service Precautions/Technician Safety Information

NOTE:  Perform work precisely in sequence specified to avoid danger of short circuit.

Disconnecting 
Quiescent current retention unit

connect if possible.  

Ground lead on battery

disconnect and remove pole terminal.  

Shield on positive terminal

swing open.  

Positive lead

disconnect from battery and remove battery terminal.

Connecting 
Positive battery terminal

connect to battery.  

Shield on positive terminal

swing shut.  

Ground pole terminal on battery

connect.  

If connected

disconnect quiescent current retention unit.

NOTE:  If quiescent current retention unit was connected, skip last step!

After connecting the battery perform the following work:

Set clock in instrument cluster. 
Code radio.  
Where applicable code automatic pilot system (APS) and load language.
Synchronize power windows.  
Set timer for stationary heater, where applicable.  
On vehicles with ADS reactivate steering angle senso.

 