Because refrigerant R134a does not contain chlorofluorohydrocarbons (CFCs), at normal temperatures it does not pose a threat to the environment or to
the earth's protective ozone layer, both considerable assets relative to conventional refrigerant gases.

Nevertheless, the refrigerant should be evacuated only with approved evacuation, processing and charging equipment with integral disposal and
reprocessing capabilities.

AH86.61-P-0004-01H Notes on Handling Components For Refrigerant Circuit In Refrigerator Box

AH86.61-P-0004-01H Notes On Handling Components For Refrigerant Circuit In Refrigerator Box

- with CODE (Z07) Top protection with refrigerator box

In the event of coolant loss, e.g. when lines are damaged, always empty, evacuate and charge system.

The refrigerator box and the compressor are supplied as replacement parts precharged with R 134a refrigerant.

The refrigerator box and the compressor can be removed and installed without emptied, evacuating and charging the system thanks to the automatically
closing valves in the connectors.