Central Control Module: All Technical Service Bulletins
Computer/Controls - Upper Control Panel Cont Unit Faults

Functional defects after installation of upper control panel control unit YoM 09/01 in vehicles with code 806 (start of series production)

Topic number

LI54.21-P-048424

Version

1

Design group

54.21 Control modules/modules

Date

11-23-2009

Validity

Model series 221 with code 806 (start of series production)

Reason for change

Reason for block

Complaint:

After installation of an upper control panel control unit (UCP) modification year 09/1 (A221 905 27 00 or A221 905 29 00) in vehicles with code 806
(start of series production), the following faults may occur:

^ PTS switch: Function LED permanently illuminated, function not impaired

^ Ambiance illumination in cockpit trim strip nonfunctional

^ In the quick test, fault 9049 (incorrect variant of cockpit switch group) and 9050 (incorrect variant of rotary light switch) are current and stored.

^ On vehicles from USA and Canada, the "Air recirculation comfort closing" function for the windows and sliding roof via the air recirculation button is

nonfunctional.

Cause:

The UCP evaluates the modification year information of the CGW on the CAN incorrectly and thus treats the described functions differently than in the
year of production startup due to changes in the model refinement.

Remedy:

No remedy is available at the present time. Flashware is being prepared. We will inform you via TIPS as soon as this is available.