mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Refrigerant Oil > < Refrigerant Control Solenoid Valve|Locations|Page 10338
Page 1
background image

Refrigerant Control Solenoid Valve: Service and Repair

AR83.50-P-9000M Remove/Install Rear Air Conditioning Refrigerant Shutoff Valve

- with CODE (582) Rear air conditioning

DANGER:

-

Explosion hazard when performing welding or brazing work on closed air conditioning. Poisoning hazard from inhaling overheated 
refrigerant vapors. Injury hazard from skin and eye contact with liquid refrigerant.

-

Do not perform any type of welding work on closed air conditioning system or in its vicinity. Smoking and open flame prohibited.

-

Wear protective goggles and protective gloves, work only in well-ventilated rooms. Perform repair work on air conditioning circuit only
with system emptied.

CAUTION:  Protect air conditioning circuit and components from moisture during repair work.

1

Empty air conditioning (recycle), evacuate, charge, check for leaks

CAUTION:  Add quantity of compressor oil removed to refrigerant circuit when charging air conditioning (new oil).

2

Remove left front wheel

3

Remove left front inner fender

4

Unscrew plastic nut (1)

5

Unscrew 2 union nuts (2)

CAUTION:  Close openings (parts kit).

NOTE:  Installation:
1. Renew O-rings
2. Moisten thread with compressor oil.

-

Union nut for rear air conditioning shutoff valve:  17 N.m

6

Unscrew 4 plastic nuts (3)

7

Remove undercarriage paneling (4)

8

Carefully pull line (5) out of grommet and disconnect rear refrigerant shutoff valve connector (Y67x1)

9

Remove rear refrigerant shutoff valve (Y67)

10

Replace receiver/drier

11

Install in opposite order.

Refrigerant Oil > < Refrigerant Control Solenoid Valve|Locations|Page 10338