Air Door Actuator / Motor: Specifications

PERMITTED LEAKAGE:

Per Vacuum Circuit [1] ...........................................................................................................................................................................  30 mbar/min. [2]
Vacuum Valve Block .....................................................................................................................................................................  50 mbar in 10 min. [3]
Valve Block (Y11) .........................................................................................................................................................................  50 mbar in 10 min. [3]
Other Components ...................................................................................................................................................................................  20 mbar/min. [3]

_______________________________________
[1]:  without vacuum reservoir.
[2]:  at 400 mbar vacuum.
[3]:  at 300 mbar vacuum.