mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Base Module (Compressor Cutout Control)|Page 7057 > < Base Module (Compressor Cutout Control)|Page 7055
Page 2
background image

Pin wrench 000 589 00 05 00

Push spring plate onto compressor shaft and tighten screw to 16 ± 1.0 Nm.

Check gap using valve gauge and correct with shims if necessary.

 
Note concerning solenoid coil (71)

To open plug housing, unscrew both screws (arrows).
Take out cable to solenoid coil.