3 screws (4)

Unscrew.

11 clips (94)

Press out and remove frame (90).

Plug connections M4x1, M4x2

Disconnect

6 screws (84) 

Unscrew.

Auxiliary fan

Remove.

Auxiliary fan

Disconnect, unscrew 2 screws (88).

Install

In reverse sequence whilst lubricating the connection thread with compressor oil (refer to note).

Receiver dehydrator

Renew. See: Receiver Dryer/Service and Repair

Air conditioner

Evacuate, refill, check function and leaks; only run engine at idle in the first 4 minutes.

NOTE:  If the condenser is not reinstalled immediately, flush out the condenser with nitrogen. Then seal off the connection with plugs. When
renewing the condenser, fill it with 20 cubic cm compressor oil.

Function check

Perform by disconnecting plug on coolant temperature sensor for air conditioner B10/8 and setting 310 Ohm (stage I) or 250 Ohm (stage II) with
ohm decade (124 589 096 300), connect battery, switch on ignition and set control unit (KLA) to "Auto". Auxiliary fans rotate clockwise.

NOTE:  Parts which have come into contact with compressor oil for R12 or R134a may only be installed in systems operating with the same 
refrigerant.

 

Special tool

Tightening torques

Nm

Lower line on condenser

24 ± 4

Upper line on condenser

17 ± 3