mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Cigarette Lighter > < Brake Pad Wear Sensor|Service Precautions|Page 9109
Page 1
background image

Charge Lamp/Indicator: Description and Operation

GF54.30-P-3007A Charge Indicator Lamp, Exterior Lamp Failure

Terminal 61 is used for the generator indicator lamp. When the ignition is On the excitation voltage is applied to it and the generator voltage when the
engine is running. However, a terminal is required for some systems (e.g. exterior lamp indicator) which

-

is exactly at ground potential (low level), when the engine is not running with the ignition On

-

is exactly at least 10.5 V (high level), when the voltage at terminal 61 exceeds a particular voltage or the engine speed exceeds a particular
threshold (480 rpm).

Terminal 61e is used for this (engine running recognition/speed threshold value).
Terminal 61e is produced in instrument cluster (A1) in accordance with the sketched circuit diagram:
An electronic system is ...via terminal 15

Terminal 61 and the speed signal are used as input signals which reach the instrument cluster via the CAN data bus.
If a particular speed or a particular voltage threshold at terminal 61 is exceeded, the transistor switches off and terminal 61e goes to high level (terminal
61 and the speed signal are interlinked to terminal 61e via an OR function. Also refer to table.)

The maximum current at terminal 61e is approx. 2 mA at high level and approx. 350 mA at low level. The switching delay is 0.5 seconds in each case.

Exterior lamp indicator lamp and charge indicator lamp

The input signal of terminal 61 and the speed signal are used for engine running recognition. Depending on these input signals the exterior lamp failure
indicator lamp (A1e14) or the generator charge indicator lamp (A1e5) is actuated (refer to table).

The instrument cluster also passes on the status of terminal 61e as a CAN message. The information is consequently available to all bus participants.

On models 163 and 168 terminal 61e is only made available as a CAN message. There is no discrete terminal 61e line.