mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Procedures|Page 6494 > < Procedures|Page 6492
Page 29
background image

15. Replace O-rings (5b).

16. Replace O-ring (4f) and shaped wedge (4g) in housing.

Check radial seal ring (4e), replace if required.

NOTE:
If oil escapes from the servo circuit to the level Circuit or vice versa. the cause is in the radial seal ring (4e).

17. Withdraw radial seal ring (4e) with internal extractor 000 589 33 33 00. Check bronze bush in housing (4) for damage and wear, replace if

required

18. Remove flow Control valve (2c) and Compression spring (2j) from pump housing (2).

CAUTION:  When removing the locking ring (2a), ensure that the housing bore is not damaged.

Procedures|Page 6494 > < Procedures|Page 6492