SL 500 (230.475) V8-5.0L (113.963) (2004)
The air direction can be controlled via the separately adjustable slats, the two hinge-mounted center nozzle and lateral nozzles as desired, either upwards,
downwards to the left or right or even to the center.
Warm air button
pressing the warm air button (7), warm air flows to the center and lateral nozzles. The escaping air is at the temperature set on the AAC pushbutton
control module (N22).
Cold air button
Pressing the cold air button (8) opens the diverter flap, thus enabling cold air to flow to the center and lateral nozzles. The escaping air is colder than the
temperature set on the AAC pushbutton control module (N22).
GF83.10-P-2174R Central and Lateral Nozzle Control System, Location/Task/Function
GF83.10-P-2174R Central And Lateral Nozzle Control System, Location/task/function
Component Identification
GF83.25-P-2101-01R Air Distribution Switch, Function
GF83.25-P-2101-01R Air Distribution Switch, Function
- with CODE (581) Automatic air conditioning
Function
The air distribution switches are combined with the Auto button ( AUTO ). The air distribution switch can be manually separated (right and left sides) or
automatically set:
^
Manual, Auto button out ( AUTO )
^
Automatic, Auto button in ( AUTO )
Turning the air distribution switch on the AAC pushbutton control module (N22) actuates the various air distribution duct actuators via AC bus.